#!/usr/bin/env python
# -*- coding: utf-8 -*-

import time
import datetime

# Example for output from agent
# ---------------------------------------------------------
#<<<fhem>>>
#Detected devices: Bad.Temp Dachboden.Temp Gaestezimmer.Temp Partyraum.Temp Schlafzimmer.Temp  
#Bad.Temp				          Bad.Temp                         TYPE		            LaCrosse
#		     2016-11-16 08:39:41  Bad.Temp		                   battery              ok
#		     2016-11-16 08:39:41  Bad.Temp		                   dewpoint             15.1
#		     2016-11-16 08:39:41  Bad.Temp		                   humdiff              0
#		     2016-11-16 08:39:41  Bad.Temp		                   humidity             83
#eg.bad.waschmaschine_pwr		  eg.bad.waschmaschine_pwr         TYPE		            Revolt
#		     2016-11-15 16:54:48  eg.bad.waschmaschine_pwr         avgpower             263.19
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         current              0
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         energy               9.27
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         frequency            50
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         pf		            0
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         power		        0
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         state		        P:   0.0 E:   9.27 V: 226 C:   0.00 F: 50 Pf: 0.00
#		     2016-11-16 09:18:07  eg.bad.waschmaschine_pwr         voltage              226
#eg.wz.heizung		              eg.wz.heizung		               TYPE		            CUL_HM
#				                  eg.wz.heizung		               model		        HM-CC-RT-DN
#		     2016-11-15 09:46:13  eg.wz.heizung		               Activity             alive
#		     2016-11-15 23:03:10  eg.wz.heizung		               CommandAccepted      yes
#		     2016-11-07 06:01:06  eg.wz.heizung		               D-firmware           1.4
#		     2016-11-07 06:01:06  eg.wz.heizung		               D-serialNr           MEQ0252852
#		     2016-11-07 06:04:23  eg.wz.heizung		               PairedTo             0x5FF2BE
#		     2016-11-07 06:04:23  eg.wz.heizung		               R-backOnTime         10 s
#		     2016-11-07 06:04:23  eg.wz.heizung		               R-btnLock            on
## ---------------------------------------------------------

def inventory_fhem(info):
	# Detected devices: Bad.Temp Dachboden.Temp Gaestezimmer.Temp
	line = info[0]
	if len(line) > 2:
		for device in line[2:]:
			yield device, {}

def check_fhem(item, params, info):
	# [[u'Detected', u'fhem:', u'Bad.Temp', u'Dachboden.Temp', u'Gaestezimmer.Temp', u'Partyraum.Temp', u'Schlafzimmer.Temp'], [u'Bad.Temp', u'TYPE', u'LaCrosse'], [u'2016-07-14', u'13:15:07', u'state', u'T:', u'21.4', u'H:', u'77'], [u'2016-07-14', u'13:15:07', u'dewpoint', u'17.2'], [u'Dachboden.Temp', u'TYPE', u'LaCrosse'], [u'2016-07-14', u'13:15:10', u'state', u'T:', u'23.5', u'H:', u'53'], [u'2016-07-14', u'13:15:10', u'dewpoint', u'13.4'], [u'Gaestezimmer.Temp', u'TYPE', u'LaCrosse'], [u'2016-07-14', u'13:15:10', u'state', u'T:', u'22.8', u'H:', u'66'], [u'2016-07-14', u'13:15:10', u'dewpoint', u'16.1'], [u'Partyraum.Temp', u'TYPE', u'LaCrosse'], [u'2016-07-14', u'13:15:12', u'state', u'T:', u'23', u'H:', u'59'], [u'2016-07-14', u'13:15:12', u'dewpoint', u'14.6'], [u'Schlafzimmer.Temp', u'TYPE', u'LaCrosse'], [u'2016-07-14', u'13:15:08', u'state', u'T:', u'22.8', u'H:', u'59'], [u'2016-07-14', u'13:15:08', u'dewpoint', u'14.4']]

	fwarn, fcrit = None, None

	if "level_data_age" in params:
		dage_warn, dage_crit = params["level_data_age"]
	if "level_temp_max" in params:
		tmax_warn, tmax_crit = params["level_temp_max"]
	if "level_temp_min" in params:
		tmin_warn, tmin_crit = params["level_temp_min"]


	# See if any checks are diabled (set to 0)
#	if dage_warn != None and dage_warn == 0:
#		dage_warn = None;
#	if dage_crit != None and dage_crit == 0:
#		dage_crit = None;
#	if cbwarn != None and cbwarn == 0:
#		cbwarn = None;
#	if cbcrit != None and cbcrit == 0:
#		cbcrit = None;
	

	errorlevel, warnlevel = 0, 0

	model = ""
	output = []
	data = {}

#	## bugfix, at beginning all timestamp up-to-date 
#	## necessary because some devices don't send all data (weather-provider has no battery)
#	battery_timestamp, dewpoint_timespamp, state_timestamp = time.time(), time.time(), time.time()

	errorlevel = 0
	ourstatus = 0
	device = ""
	for line in info:
		if len(line) == 4 and line[2] == 'TYPE':
			if line[0] == item:
				dev_type = line[3]
				ourstatus = 1
			elif ourstatus == 1:
				break
		elif ourstatus == 1:
#			if line[0] == model:
#				model = line[0]
			if len(line) > 3 and line[3] != 'null':
				data[line[3]] = {}
				data[line[3]]['value']=line[4]
				data[line[3]]['time']=( "%s %s" % (line[0], line[1]))
				data[line[3]]['channel'] = line[2]
	
	if ourstatus == 0:
		return (3, "UNKNOWN - %s - %s " % (device, dewpoint))

	perfdata = []

# ##################################################################

	## key 		=> variable_name
	## title 	=> readable output
	## unit		=> °C, &, V., kmh, ... (for output)
	## channel	=> filter for channel (HomeMatic)
	## show		=> print if no error
	## perfd	=> print perfdata
        for key, title, unit, channel, show, perfd in [
	     ##	key			 title			 unit		channel		show	perfd
	     ##  -------	 -------		 -------	------- 	----	-----
        ('temperature',  'temperature',  u'°C',		'',		    1,	    1),
        ('desired-temp', 'desiredtemp',  u'°C',		'',		    1,	    1),
		('humidity',     'humidity',     u'%',		'',		    1,      1),
		('dewpoint',     'dewpoint',     u'°C',		'',		    1,      1),
		('contact',      'contact',		 '',		'',		    1,      1),
		('valveposition','valveposition',u'%',		'',		    1,      1),
		('battery',      'battery',		 '',		'',		    1,      0),
		('batteryLevel', 'batteryLevel', 'V',		'',		    1,      1),
		('controlMode',  'controlMode',	 '',		'Clima',    0,      0),
		('Activity',	 'activity',	 '',		'',		    0,      1),
		('power',		 'power',		 'kWh',		'',		    1,      1),
		('energy',		 'energy',		 'W',		'',		    1,	    1),
		('voltage',		 'voltage',		 'V',		'',		    1,	    1),
		## HomeMatic
		('measured-temp',  'temperature',   u'°C',	'',		    1,      1),
		('actuator',       'valveposition',	u'%',	'',		    1,      1),
		('R-btnLock',	   'btnLock',		'',		'',		    0,	    0),
		('R-globalBtnLock','globalBtnLock', '',     '',	        0,      0),
		('R-modusBtnLock', 'modusBtnLock',	'',		'',		    0,	    0),
		## MilightDevice (and others?)
		('brightness',	   'brightness',	u'%',	'',		    1,	    1),
		('brightness_on',  'brightness_on',	u'%',	'',     	0,      1),
		('ct',    		   'ct'			    ,'K',   '', 	    1,      1),
		('hsv',    		   'hsv',     		'',     '',     	0,      0),
		('transitionInProgress','transitionInProgress', '', '',	0,      1),
		## MiLightBridge
		('protocol',	   'protocol',		'',	 	'',		    0,	    0),
		('checkInterval',  'checkInterval', 's',    '',         0,      0),
		('sendInterval',   'sendInterval',  's',    '',         0,      0),
        ]:
	  ## reset
	  display_value = "" 
	  ignoreit	= ""
#	  var_data_age = ""


	  ## check if device output data (temperature, humidity, ... )
	  try:
		if data[key]['value']:
		    value = data[key]['value']

		    ## build dynamic variable names ...
		    var_max = 'level_%s_max' % title
		    var_min = 'level_%s_min' % title
		    var_data_age = '%s_date' % title
		    var_plain = 'var_%s' % title	## e.g. contact: open (var_plain => open)

	#	    print var_data_age
	#            	if  params[eval("desiredtemp_date")]:
	#			print desiredtemp_date
	#	      	pass
	#	    except:
	#	   	pass
		

		    try:
			if params[eval("var_max")]:
				## check the difference between dewpoint and temperature
				if key == 'dewpoint':
				        max_warn_dewpoint, max_crit_dewpoint = params[eval("var_max")]
				        max_warn = float(data['temperature']['value']) - max_warn_dewpoint
				        max_crit = float( data['temperature']['value']) - max_crit_dewpoint
				else:   
					max_warn, max_crit = params[eval("var_max")]
			pass
		    except:
			max_warn, max_crit = 0, 0
			pass
		    try:
			if params[eval("var_min")]:
				min_warn, min_crit = params[eval("var_min")]
			pass
		    except:
			min_warn, min_crit = 0, 0
			pass
		    try:
		        if params[eval("var_plain")]:
				var_plain = params[eval("var_plain")]
		        pass
		    except:
		        var_plain = None
		        pass

		    try:
			if eval(var_data_age) and eval(var_data_age) != "":
				local_timestamp = time.time()
				var_data_timestamp = time.mktime(datetime.datetime.strptime(eval(var_data_age) , "%Y-%m-%d %H:%M:%S").timetuple())
				data_age = int( ( local_timestamp - var_data_timestamp ) / 60 )
			pass
		    except:
			## bugfix, at beginning all timestamp up-to-date 
			## necessary because some devices don't send all data (weather-provider has no battery)
			data_age = 0
			pass


	#	    if data_age > dage_crit:
	##		 print ("data_age = %s, dage_crit = %s" % (data_age, dage_crit))
	#               	 display_value = ("data to old [" + str(data_age)  + "min] (!!)")
	#		 errorlevel = 2
	#	    elif data_age > dage_crit: 
	#		 display_value = ("data to old [" + str(data_age)  + "min] (!)")
	#		 warnlevel = 1
	#	    else:

		    if key == 'humidity' and params['var_dewpoint_override'] == 'true':
			ignoreit = 'true'

		    ## there are sometime duplicate keys on channel like controlmode in '_Clima' and '_Climate' 
		    ## Just filter out some HomeMatic-channel
		    if channel == '' or data[key]['channel'] == "%s_%s" % (item, channel):
			    ## check critical level (max/min)
			    if ( (max_crit != 0 and float(value) >= max_crit) or (min_crit != 0 and float(value) <= min_crit) ) and not ignoreit:
				if max_crit != 0 and float(value) >= max_crit:
					display_value = ('%s%s (warn/crit at %s%s/%s%s) (!!)' % ( value, unit, max_warn, unit, max_crit, unit))
				elif float(value) <= min_crit:
					display_value = ('%s%s (warn/crit at %s%s/%s%s) (!!)' % ( value, unit, min_warn, unit, min_crit, unit)) 
				errorlevel = 2
			    ## check warning level (max/min)
			    elif ( (max_warn != 0 and float(value) >= max_warn) or (min_warn != 0 and float(value) <= min_warn) ) and not ignoreit:
				if max_warn != 0 and float(value) >= max_warn:
					display_value = ('%s%s (warn/crit at %s%s/%s%s) (!)' % ( value, unit, max_warn, unit, max_crit, unit))
				elif float(value) <= min_warn:
					display_value = ('%s%s (warn/crit at %s%s/%s%s) (!)' % ( value, unit, min_warn, unit, min_crit, unit))
				warnlevel = 1
			    elif var_plain:
				## just alert if value not identic or ignored
				if value == var_plain or var_plain == "ignore":
					if show:
						display_value = ('%s%s' % ( value, unit ))
					if perfd:
						perfdata.append( ( key , 1, ""  ) )
				else:
					display_value = ("%s (expected: %s) (!!)" % (value, var_plain))
					errorlevel = 2
					if perfd:
						perfdata.append( ( key, 0, "" ) )
			    ## define output
			    elif show:
				display_value = ('%s%s' % ( value, unit ))

			    ## define perfdata (just add numeric values)
			    if perfd and not var_plain:
				perfdata.append( ( title, value, max_warn, max_crit, "", "" ) )


			    ## not used (yet)
#			    if data_age > dage_crit:
#				 display_value += (" (data obsolet: %s min) (warn/crit at %s/%smin) (!!)" % (str(data_age), dage_warn, dage_crit))
#				 errorlevel = 2
#			    elif data_age > dage_warn:
#				 display_value += (" (data obsolet: %s min) (warn/crit at %s/%smin) (!)" % (str(data_age), dage_warn, dage_crit)) 
#				 warnlevel = 1


			    if display_value != "":
				output.append('%s: %s' % (title, display_value))
	  	pass

	  except:
		pass



# ##################################################################

  	if errorlevel > 1:
		exitcode = 2
	elif warnlevel > 0:
		exitcode = 1
	else:
		exitcode = 0

	return exitcode, ', '.join(output), perfdata


factory_settings["fhem_default_params"] = {
	"level_data_age"    	: (30, 90), 	# warn/crit for data age (min)
	"level_temperature_max"	: (26, 30), 	# warn/crit for max. temperature
    "level_temperature_min"	: (15, 12), 	# warn/crit for min. temperature
	"level_humidity_max"  	: (70, 80), 	# warn/crit for max. humidity
	"level_humidity_min"  	: (50, 45), 	# warn/crit for min. humidity
	"level_dewpoint_max"	: (3, 1),   	# warn/crit for diff to temperatur (exp. 17°C (dewp) vs 20°C(temp))
    "level_batteryLevel_min": (2.1, 2.3), 	# warn/crit for max. temperature
	"var_activity"		    : ("alive"), 	# default for alive
	"var_contact"	    	: ("ignore"), 	# default for contact
	"var_dewpoint_override"	: ("true"),	# don't alert humidity if dewpoint given
	"var_btnLock"		    : ("ignore"),	# simple button lock
	"var_globalBtnLock"   	: ("ignore"),   # full button lock
	"var_modusBtnLock"    	: ("ignore"),   # modus button lock
}

check_info['fhem'] = {
    "check_function"          : check_fhem,
    "inventory_function"      : inventory_fhem,
    "service_description"     : "FHEM %s",
    "has_perfdata"            : True,
    "group"                   : "fhem",
    "default_levels_variable" : "fhem_default_params",
}